[-2]proenzyme prostate specific antigen for prostate cancer detection: a national cancer institute early detection research network validation study.
Abstract
This study evaluated the [-2]proenzyme prostate specific antigen serum marker using a blinded reference specimen set from 3 National Cancer Institute Early Detection Research Network centers from men with an indication for prostate biopsy.
Serum was collected before biopsy from 123 men with no prior biopsy or prostate cancer history. Specimens (cancer cases 51%, noncancer controls 49%) were selected equally from the 3 sites, and analyzed for prostate specific antigen, free prostate specific antigen, [-2]proenzyme prostate specific antigen, benign prostate specific antigen and testosterone (Beckman Coulter ACCESS(R) analyzer).
There was no difference in total prostate specific antigen concentrations (noncancer 6.80 +/- 5.20 ng/ml, cancer 6.94 +/- 5.12 ng/ml) among the groups. Overall %[-2]proenzyme prostate specific antigen had the greatest area under the curve (AUC 0.69) followed by percent free prostate specific antigen (AUC 0.61). For %[-2]proenzyme prostate specific antigen maximal sensitivity was 60% and specificity was 70%. A logistic regression model combining prostate specific antigen, benign prostate specific antigen, percent free prostate specific antigen, %[-2]proenzyme prostate specific antigen, [-2]proenzyme prostate specific antigen/benign prostate specific antigen and testosterone had an AUC of 0.73. In the 2 to 10 ng/ml prostate specific antigen range %[-2]proenzyme prostate specific antigen and the model had the largest AUC (0.73). The AUC for percent free prostate specific antigen was 0.53. Specificities for %[-2]proenzyme prostate specific antigen, the logistic regression model and percent free prostate specific antigen at 90% sensitivity were 41%, 32% and 18%, and at 95% sensitivity were 31%, 26% and 16%, respectively.
%[-2]proenzyme prostate specific antigen was the best predictor of prostate cancer detection compared to percent free prostate specific antigen, particularly in the 2 to 10 ng/ml total prostate specific antigen range. These findings provide a rationale for broader validation studies to determine whether %[-2]proenzyme prostate specific antigen alone can replace other molecular prostate specific antigen assays (such as percent free prostate specific antigen) for improving the accuracy of prostate cancer early detection. These findings also support the usefulness of well characterized, carefully collected reference sets to evaluate new biomarkers.
Biomarkers
The following biomarkers make reference to this publication:
Protocols
The following 2 protocols are associated with this publication:
EDRN PI Authors
Medline Author List
- Chan DW
- Feng Z
- Kagan J
- Partin AW
- Sanda MG
- Sokoll LJ
- Thompson IM
- Wang Y